Sample AF01: Low-rise concrete masonry (CMU) in Afghanistan

Basic Information | Commentary

Basic Information

 

Building Overview

Low-rise masonry structures are very popular in Kabul and major cities in Afghanistan. Here, fourteen CMU dominant buildings have been selected as specimens for this study; nine specimens are two-story existing buildings and five specimens are three-story recently designed buildings. The buildings have different reinforcement details that are commonly used in Afghanistan. All the buildings have the same wall thickness of 200mm but the masonry design compressive strengths (fm) are different. And the nominal yielding strengths of reinforcing bars are equal 345MPa for all the buildings. An outline of the buildings is presented in Table below. It is assumed that all the specimens are located in very dense soil and soft rock that is classified as C-type in the Afghanistan Structural Code (ASC).

Database

Basic rule of file name:     (name)_(number of story)_(structural type)

Building information includes the source information of creating input data of STERA_3D, such as plan, elevation, section, material strength.

  Building Information (*.pdf) Input file (*.stera) STERA_3D version Author Date
1 B01_2F_CMU_AF B01_2F_CMU_AF 9.3 Ahmad Naqi 2017.10.08
2 B02_2F_CMU_AF B02_2F_CMU_AF 9.3 Ahmad Naqi 2017.10.08
3 B03_2F_CMU_AF B03_2F_CMU_AF 9.3 Ahmad Naqi 2017.10.08
4 B04_2F_CMU_AF B04_2F_CMU_AF 9.3 Ahmad Naqi 2017.10.08
5 B05_2F_CMU_AF B05_2F_CMU_AF 9.3 Ahmad Naqi 2017.10.08
6 B06_2F_CMU_AF B06_2F_CMU_AF 9.3 Ahmad Naqi 2017.10.08
7 B07_2F_CMU_AF B07_2F_CMU_AF 9.3 Ahmad Naqi 2017.10.08
8 B08_2F_CMU_AF B08_2F_CMU_AF 9.3 Ahmad Naqi 2017.10.08
9 B09_2F_CMU_AF B09_2F_CMU_AF 9.3 Ahmad Naqi 2017.10.08
10 B10_3F_CMU_AF B10_3F_CMU_AF 9.3 Ahmad Naqi 2017.10.08
11 B11_3F_CMU_AF B11_3F_CMU_AF 9.3 Ahmad Naqi 2017.10.08
12 B12_3F_CMU_AF B12_3F_CMU_AF 9.3 Ahmad Naqi 2017.10.08
13 B13_3F_CMU_AF B13_3F_CMU_AF 9.3 Ahmad Naqi 2017.10.08
14 B14_3F_CMU_AF B14_3F_CMU_AF 9.3 Ahmad Naqi 2017.10.08

 

Go to top of page

Commentary

B01_2F_CMU: How to prepare input date for CMU buildings

Select "Option"> "Structure" from the menu. Leave degrees of freedom number (1,2) in the horizontal X and Y directions and restrict other degrees of freedom number (345678).

Since the numerical values of the restoring force characteristic of each CMU is defined directly, select "option"> "member" from the menu and change Passive Damper to be "Considered".

Set the numerical values of the restoring force characteristic of each Damper type.